Since the Dome Siren is 100% integrated with Vera installation is a snap! follow along to get started:
Initial Setup
Pairing
1. Under 'Devices' select 'Add Device'
2. Under 'Alarms' select the Dome Wireless Z-Wave Plus Siren and follow the prompts
3. When you're done your Siren is ready to use!
Interface
Once your Siren is installed, you can access it under Devices
Click on the arrow button on the Siren to open up the device menu
If you would like to change the settings on your Siren, you simply click on Device Options
Under Device Options you can change the settings as follows:
NOTE: All options listed below are 1 byte hex
1: This parameter sets the volume of the Siren (primary) sound. There are three possible volume levels available.
01 (Low Volume)
02 (Medium Volume)
03 (High Volume)
2: This parameter defines the length of the Alarm/primary notification.
01 (30 Seconds)
02 (1 Minute)
03 (5 Minutes)
FF (Plays Until Battery is Depleted)
3: This parameter defines the number of times the Chime/Secondary Notification will play.
00 (Chime Will Not Play)
01~FE (1~254 Cycles)
FF (Does Not Stop)
4: This parameter sets the volume of the Chime (secondary) sound. There are three possible volume levels available.
01 (Low Volume)
02 (Medium Volume)
3 (High Volume)
5: The Siren offers ten different sounds to use as the Siren (primary) notification. This parameter sets the Siren (primary) notification sound.
01 ~ 0A (Sound Index Number) 0A
6: If Parameter 7 is set to 02, the Siren will play a secondary chime sound instead of the main alarm. The Siren offers ten different sounds to use as the Chime (secondary) notification. This parameter sets the Chime (secondary) notification sound.
01 ~ 0A (Sound Index Number)
7: This Parameter toggles between the Primary and Secondary notification sound to be played when the Siren receives a BINARY_SWITCH_SET(FF) command.
01 (Primary Notification Will Play)
02 (Secondary Notification Will Play)
8: This Parameter enables or disables the Flashing LED Ring (strobe) accompanying the Primary Notification.
01 Enable/Disable Primary Notification Strobe
00 (LED Ring Will Not Flash)
01 (LED Ring Will Flash)
9: This Parameter enables or disables the Flashing LED Ring (strobe) accompanying the Secondary Notification.
00 (LED Ring Will Not Flash)
01 (LED Ring Will Flash)